Product classification
C2 Disposable Suction Oral Care Kit
hiddenValue
Details Introduction
- Product Description
-
[Product Name]Disposable useSuction-type oral care kit
[Product Specifications] See product packaging
[Main Components] Composed of oral suction tube (including brush head), medical examination gloves, disposable dressing tweezers, medical isolation pads, cotton balls, rinsing device, and tongue depressor. All instruments in the package are classified as Class I medical devices and are provided non-sterile. For single use.Serial Number
Accessory Name
Product Description
Category Directory
Model Specifications Configuration
C1
C2
C3
1
Oral suction tube (including brush head)
Composed of silicone brush head, handle,rinsing tube, rinsing tube connectorfor use with negative pressure equipment and negative pressure drainage bags.Provided non-sterile.Sterilization or disinfection should be performed by the user organization according to the instructions before use (if applicable).
17-04-20
√
√
√
2
Medical examination gloves
Made of polyethylene material. Has sufficient strength and barrier performance..Provided non-sterile, for single use.
14-14-04
√
√
√
3
Disposable dressing tweezers
Composed of a pair of overlapping blades. Made of polystyrene material.Provided non-sterile.Sterilization or disinfection should be performed by the user organization according to the instructions before use (if applicable). Not for use under endoscopy.
02-05-02
/
√
√
4
Medical isolation pad
Made of non-woven fabric and plastic composite, cut and sewn.Provided non-sterile, for single use.
14-15-05
/
√
√
5
Cotton ball
Mainly composed of cotton. Does not contain disinfectants. Provided non-sterile, for single use.
14-16-10
/
√
√
6
Rinsing device
Composed of outer casing, core rod, and piston. Fill with rinsing solution before use, or connect with related rinsing equipment or devices to form a rinsing system, which can rinse the patient's area. Provided non-sterile (if used in a sterile environment, should be sterilized before use). Does not contain rinsing solution.
14-07-01
/
√
√
7
Tongue depressor
Made of wooden material. Provided non-sterile, for single use.
07-01-01
/
/
√
[Scope of Application] For oral cleaning and care in medical institutions.
[Usage Method]
1. Open the packaging bag, connect the negative pressure device as needed, and wear examination gloves.
2. Connect the handle machine end to the negative pressure device, then connect the rinsing tube connector to the infusion device or rinsing device; place the patient end of the oral suction tube (including brush head) into the patient's mouth, block the decompression port, so that the tube body is in a sealed state, forming negative pressure, and start suctioning phlegm. Slowly inject cleaning liquid through the rinsing tube into the patient's mouth, controlling the speed at about 80 drops/min; use the silicone brush head to clean the patient's mouth and between teeth, while rinsing and brushing, simultaneously suctioning away cleaning liquid, phlegm, saliva, etc. During the operation, pay attention to control the input speed of the cleaning liquid and the negative pressure to avoid causing the patient to cough.
3. Lay the isolation pad as needed, use the dressing tweezers to pick up cotton balls to wipe phlegm around the lips (suitable for C2 and C3 types).
4. Use the tongue depressor to press the patient's tongue for better operation (suitable for C3 type).
5. After the oral cleaning is complete, first stop the input of cleaning liquid, then close the negative pressure and remove the oral suction tube (including brush head).
[Contraindications, Precautions, Warnings, and Instructions]
1. Be sure to connect a waste liquid collection bag between the negative pressure source and the product and clean it in a timely manner to avoid waste liquid directly entering the negative pressure source equipment, which could damage the equipment. 2. It is recommended to adjust the negative pressure source within an appropriate range to ensure that excessive negative pressure does not cause harm to the patient.
3. During use, if the product cannot suction, please immediately remove the product and perform relevant checks and cleaning. If it cannot be restored, please replace it with a new product. 4. This product is for single use only, dispose of after use. 5. Before use, please confirm the expiration date and check if the packaging and product are intact. Do not use if the product is damaged, expired, or the packaging is broken. 6. When not in use, keep the decompression port in the open state. 7. When the product is used for oral care, it is not suitable for agitated, mentally symptomatic, or severely ill patients with oral ulcers. For patients with clenched jaws, use an opener with two people if necessary. 8. During use, pay attention to observe the firmness of the connection between the brush head and the tube body. 9. This product is for single use by one patient only. 10. This product should be purchased and used under the guidance of medical personnel. 11. Use with caution for those allergic to silicone material.[Illustrations and Symbol Definitions]
Production Date
Expiration Date
Do not reuse
Do not use if packaging is damaged
[Storage and Transportation Conditions] 1. This product should be stored in a clean indoor environment at room temperature, with a relative humidity not exceeding 80%, free from corrosive gases, and well-ventilated and dry. 2. During transportation and storage, prevent moisture, heat, direct sunlight, and heavy pressure; do not freeze.
[Product Filing Certificate Number] Guinan Machinery Registration 20240104
[Production Filing Certificate Number] Guinan Drug Supervision Machinery Production Registration 20210015
[Product Technical Requirements Number] Guinan Machinery Registration 20240104
[Production Date] See product single packaging [Shelf Life] Two years
[Filer/Production Enterprise and After-sales Unit] Guangxi Yihe Medical Technology Co., Ltd. [Contact Information] Phone: 0771-6262566
[Address/Production Address] No. 146 Wuhua Avenue, ASEAN Economic and Technological Development Zone, Guangxi - Changgui ASEAN Science and Technology Park, Building 12
[Instruction Manual Preparation Date] October 7, 2024
[Instruction Manual Version] A/0
Key words:
Hand Hygiene Disinfection | Skin and Mucous Membrane Disinfection
Product Consulting